IP POINT HART IN
A-IP.HART-I
IP POINT HART OUT
A-IP.HART-O
The IP-Point-HART module can convert any analog device into either EtherNet/IP, Modbus-TCP, or DNP3 TCP/UDP protocols. This includes input and output HART and non-HART analog devices.
- HART to EtherNet/IP
- Analog Input or Output
- Supports DNP3 with Secure Authentication
- Supports Modbus-TCP
- Supports CC-Link
- Supports Multidrop
- Supports Custom HART message
- Supports Burst Mode
- HART Data & Diagnostics
- Onboard 1000 point trend
- DTM Available
- M20 and NPT thread options

Overview
The IP-Point-HART module can convert any analog device into either EtherNet/IP, Modbus-TCP, CC-Link, or DNP3 TCP/UDP protocols. This includes 4 to 20 mA input and output devices with or without HART communications as well as 0 to 20 ma devices without HART.
The IP-Point-Hart is available in Input or Output variations:
- A-IP.HART-I for HART input devices like process instruments.
- A-IP.HART-O for HART output devices like valve positioners.
The waterproof module is designed to screw directly into the HART field device simplifying installation. Power (24V) and Ethernet is connected to the device through the use of industry standard M12 connectors. The M12 connectors are supplied with the device and can be connected in the field.
The conversion to EtherNet/IP enables a HART device to be added directly into a Rockwell Automation Logix IO tree. The Modbus-TCP option enables a HART field device to be viewed as a Modbus Slave. The DNP3 option converts a HART field device into a DNP3 Outstation. The DNP3 option, also supports Secure Authentication, ensuring secure communications across the Ethernet network.
The HART module also supports CC-Link and can operate as a CC-Link Slave allowing a CC-Link Master (eg. Mitsubishi controller) to connect to it and exchange data with the HART field device.
In addition, a rich collection of process and diagnostic information is provided directly into Logix, without the use of any explicit messaging. HART commands can also be relayed to the device using an EtherNet/IP message relay object. A DTM (Device Type Manager) is available further simplifying device configuration and management using an FDT frame. A built-in webserver provides detailed diagnostics of system configuration and operation as well as field device specific diagnostics.
Specification
Electrical
Specification | Rating |
Power requirements |
Input: 10 – 28V DC 30 mA @ 24 VDC - With no field device attached. 52 mA @ 24 VDC - With a field device at 22mA. 50 mA @ 12 VDC - With no field device attached. 72 mA @ 12 VDC - With a field device at 22mA. |
Power consumption |
0.8 W - With no field device attached. 1.4 W - With a field device at 22mA. 1.7 W - With input channel shorted (IP Point HART In)
|
Connector (Power) | Binder M12-A, 5 contact, cable outlet: 4-6 mm, female cable connector, plastic lock, screw terminal connection. (Part Number: 99 0436 10 05) |
Connector (Ethernet) | Binder M12-D, 4 contact, cable outlet: 6 - 8 mm, shieldable, CAT 5 screw terminal connection, static ring version (Part number : 99 3729 810 04) |
Conductors | 20 AWG (Red, Black, Green) |
Enclosure rating | IP66 |
Temperature | -20 – 70 °C |
Emissions | IEC61000-6-4 |
ESD Immunity | EN 61000-4-2 |
Radiated RF Immunity | IEC 61000-4-3 |
EFT/B Immunity | EFT: IEC 61000-4-4 |
Surge Immunity | Surge: IEC 61000-4-5 |
Conducted RF Immunity | IEC 61000-4-6 |
Ethernet
Specification | Rating |
Connector | RJ45 |
Conductors | CAT5 STP/UTP |
ARP connections | Max 20 |
TCP connections | Max 20 |
CIP connections | Max 10 |
Communication rate | 10/100Mbps |
Duplex mode | Full/Half |
Auto-MDIX support | Yes |
Analog Input Channel (A-IP.HART-I)
Specification | Rating |
Number of channels | 1 |
ADC resolution | 12 bit |
Input impedance | 247.5Ohm |
Accuracy (calibrated @ 25 degC) | < 0.15% |
Accuracy (uncalibrated) | < 0.30% |
Rangetd> | 0 - 22mA |
Current Limit | 34mA |
Analog Output Channel (A-IP.HART-O)
Specification | Rating |
Number of channels | 1 |
DAC resolution | 16 bit |
Drive | 50 - 1170 Ohm Resistive < 50 mH Inductive |
Accuracy (calibrated @ 25 degC) | < 0.15% |
Accuracy (uncalibrated) | < 0.30% |
Rangetd> | 0 - 22mA |
Certifications
Specification | Rating |
CE Mark | ![]() |
UL Listed FILE: E494895 |
CLASS 1, DIV 2, GROUPS A, B, C, D
|
ODVA Conformance | ![]() |
RoHS2 Compliant | ![]() |
Product Dimensions
Power Connector Dimensions
Ethernet Connector Dimensions
Downloads
Documents




Examples
EDS Files


Firmware




DTMs